6 Factory Fire Evacuation Tips: Assembly Points, Headcounts, and Fire Wardens
Factory fire evacuation tips covering chain of command, exit routes, assembly points, worker headcounts, and fire units under Indonesia's Kepmenaker 186/1999.
By Diginfo AssistantPublished 4 min read
Language:Bahasa Indonesia中文
A factory fire evacuation only works when the plan is written and practiced before anything happens. Guidance from the US Occupational Safety and Health Administration (OSHA) covers several core elements, including a chain of command, exit routes, assembly areas, and accounting for workers. In Indonesia, similar duties are set out in Ministry of Manpower Decree No. KEP.186/MEN/1999 on Fire Response Units in the Workplace.
Below are six practical steps plant managers can apply.
1. Decide Who Orders the Evacuation
The evacuation plan should clearly name the person authorized to order an evacuation or a shutdown. OSHA also asks for a chain of command, meaning the order of decision-makers when the lead official is not on site.
The plan should also define which conditions require evacuation and when sheltering in place is the better choice. This clarity prevents conflicting orders in the first minutes of a fire.
2. Keep Exit Routes Clear
Exit routes should be clearly marked, well lit, and wide enough for the number of people using them. They must be free of obstructions at all times. OSHA warns that routes should not expose workers to additional hazards, for example by passing chemical storage areas.
Build maps from floor plans that show exits, assembly points, fire extinguishers, first aid kits, and spill kits, which are supplies for containing leaks. Post the maps where every worker can see them. Evacuation wardens should also be trained on alternate routes in case the main route is blocked by fire or smoke.

3. Choose a Safe, Spacious Assembly Point
Outdoor assembly points are usually parking lots or open spaces away from busy streets. They must be large enough to hold every worker. OSHA recommends placing them upwind of the building, based on the prevailing wind, so evacuees are not exposed to smoke.
When choosing the site, also make sure that gathered workers will not interfere with rescue operations.
4. Count Workers and Track Visitors
Once everyone is out, take a headcount right away. Record the names and last known locations of anyone missing, then give the list to the official in charge. Rescuers can then go straight to the right area and avoid unnecessary searches.
Visitors, suppliers, and customers must also be accounted for, for example through a sign-in sheet at entry. OSHA suggests roughly one evacuation warden for every 20 employees. Wardens check offices and restrooms and close fire doors on the way out.
5. Set Up a Fire Response Unit
Article 5 of Kepmenaker 186/1999 divides the fire response unit into four parts. These are fire role officers, a fire response squad, a unit coordinator, and an occupational safety (K3) fire specialist who serves as technical lead.
Article 6 requires at least two fire role officers for every 25 workers. A squad and a K3 fire specialist are mandatory at light or medium-I risk sites with 300 or more workers. The same applies to all medium-II, medium-III, and heavy-risk sites. Fire role officers identify hazards, tackle fires at an early stage, and direct evacuation.
6. Prepare an Emergency Fire Plan Book
Article 2 requires management to keep an emergency fire response plan book. This applies to workplaces with more than 50 workers or with medium-to-heavy fire risk. The book covers fire hazard sources and prevention, fire protection equipment, and emergency procedures.
The same article requires regular fire drills. Procedures that exist only on paper are not enough. They need to be practiced until every worker knows their role. To record drills and worker data, companies can use a safety app.
In short, an effective fire evacuation rests on clear orders, clear routes, a safe assembly point, and an accurate headcount. All of this needs the backing of a properly staffed fire response unit and regular drills.
Sources
- Emergency Action Plan: Elements (OSHA, accessed November 22, 2026)
- Keputusan Menteri Tenaga Kerja Nomor KEP.186/MEN/1999 tentang Unit Penanggulangan Kebakaran di Tempat Kerja (JDIH Kemnaker, September 29, 1999)
- Teks KEP-186/MEN/1999 tentang Unit Penanggulangan Kebakaran di Tempat Kerja (Aswin Weblog, March 2, 2011)
- #fire evacuation
- #assembly point
- #emergency response
- #fire safety regulation