Kendal Workers Electrocuted: Portable Power Tool Lessons for Wet Areas
Two workers in Kendal, Indonesia, died of suspected electrocution on 25 November 2026. Possible causes, electrical safety rules, and a wet-area tool checklist.
By Diginfo AssistantPublished 8 min read
Language:Bahasa Indonesia中文

Two workers in Kendal Regency, Central Java, died on Wednesday, 25 November 2026, and police suspect both were electrocuted. One was mixing cement with an electric drill in Brangsong. The other was cleaning a water storage tank in the Kendal Industrial Estate and had taken a water pump in with him. Both were using portable electric equipment near water. The exact causes will only be known when the official investigations are complete.
Our condolences go to the families and co-workers of both men. This article does not assign blame. It is meant to help safety teams review how portable electric tools are used in wet areas and inside tanks.
What Happened in Kendal
Brangsong, around 08:30 WIB. A witness found a 33-year-old construction worker lying on the ground in Dukuh Beberan, Purwokerto Village, Brangsong District. The witness called neighbours for help and reported the incident to Brangsong Police. An electric drill with a cement-mixing paddle was resting on the worker's chest, and he was not wearing footwear. Nearby were a bucket of cement mortar and an extension cord reel that was still connected to the drill. Brangsong Police, the Kendal Police duty officer, the Inafis forensic team, and medical staff from Brangsong Community Health Centre attended. Medical staff confirmed that he had died. Police seized the drill and the cord reel, questioned three witnesses, and said their preliminary suspicion was electric shock from the drill he was using.
Kendal Industrial Estate, Kaliwungu, around 11:30 WIB. A helper went into a company's water storage tank to clean it. He took cleaning tools and a water pump with him. When he did not come out, a co-worker went looking for him and found him unconscious inside the tank. Kaliwungu Police, the Kendal Police duty officer and Inafis team, and the PSC 119 Kendal medical team attended. PSC 119 pronounced him dead. A Kendal Police spokesperson said the preliminary suspicion was electric shock while he was inside the tank.
| Aspect | Brangsong | Kendal Industrial Estate |
|---|---|---|
| Location | Building work, Purwokerto Village | Company water storage tank, Kaliwungu |
| Task | Mixing cement mortar | Cleaning a water storage tank |
| Equipment | Electric drill with mixing paddle on an extension reel | Water pump (power source and cabling not reported) |
| Wet factor | Wet mortar in a bucket, barefoot worker | Inside a water tank (water level at the time not reported) |
| Confined space | No | Yes |
| Status | Suspected electrocution, evidence seized | Suspected electrocution, witnesses questioned |
Possible Causes Through the Hierarchy of Controls
Everything below is a possibility to consider in your own review. None of it is an investigation finding. Shocks in wet areas often follow a familiar pattern. The tool casing or cable becomes live because of damaged insulation, water getting in, or a poor joint. Current then flows through the body to earth. Bare feet on wet ground, or standing inside a tank, make that path easier. Without residual current protection, the current is not cut off quickly enough.
| Level | Question to ask | Example controls |
|---|---|---|
| Elimination | Does mains-powered equipment need to be in the wet area or tank at all? | Drain the tank first and clean it with no electrical equipment inside |
| Substitution | Is there an alternative that does not use mains power? | Battery or extra-low-voltage mixers, manual mixing, a drum mixer, pneumatic pumps |
| Engineering | Will a leakage current be cut off at once? | An RCD/ELCB at the supply, sound insulation and earthing, a fit-for-purpose water-resistant cord reel, supply and joints kept outside the tank |
| Administrative | Is the job authorised, supervised, and monitored? | A confined-space permit, pre-use tool and cable checks, supervision, a buddy system, lockout/tagout (LOTO) on pumps and inlet valves |
| PPE | What is the worker's last line of defence? | Insulating footwear and gloves, a ban on barefoot work |
Two points stand out. First, a hand drill with a mixing paddle on an extension reel is a common sight on house-building and renovation jobs. It is often left out of risk assessments because the job is seen as minor. Second, the helper in the tank was only found when a co-worker went to look for him. That may suggest nobody was watching continuously from outside, but this has to wait for the official findings.

Relevant Indonesian Regulations
Law No. 1 of 1970 on Work Safety. Article 2(1) states that the law covers work safety in all workplaces. Article 3(1)(q) requires safety conditions that prevent workers from being exposed to dangerous electric current. Article 3(1)(f) covers the provision of personal protective equipment. Article 9(1)(a) requires management to explain workplace conditions and hazards to new workers. Article 14(c) requires management to supply mandatory PPE free of charge.
Minister of Manpower Regulation (Permenaker) No. 12 of 2015 on Electrical OHS in the Workplace. It was enacted on 9 April 2015 and promulgated on 16 April 2015. According to the Ministry of Manpower legal database (JDIH Kemnaker), it covers inspection and testing of electrical installations, equipment, and devices across generation, transmission, distribution, and use. Portable tools used on site fall under use.
Permenaker No. 33 of 2015, enacted on 16 October 2015, amended Article 10 of the 2015 regulation. According to the summary on JDIH Kemnaker, inspection and testing are carried out by Electrical OHS Specialist Labour Inspectors, company Electrical OHS Experts, and/or Electrical OHS Experts from licensed safety service firms (PJK3). Inspections take place before handover, after modification or repair, and periodically.
A note on status. JDIH Kemnaker lists both regulations as in force. We could not verify any later amendment or partial revocation against an official text while writing this article, so the current status should be checked against the official text. We do not describe other articles of the 2015 regulation because we could not verify its full text.
US comparison (OSHA). Under 29 CFR 1926.404(b)(1), US construction employers must use either GFCIs or an assured equipment grounding conductor program. GFCIs are required on 120-volt receptacles that are not part of permanent wiring. OSHA says a GFCI trips when the current going out and the current returning differ by about 5 mA, and it can trip in as little as 1/40 of a second. OSHA also notes that a GFCI does not protect against contact with two live conductors. Portable units exposed to rain must be waterproof. Indonesia uses a different supply voltage, but the lesson still applies: temporary site cabling needs leakage protection at the source.
Checklist Before Switching On a Portable Tool in a Wet Area or Tank
- Ask whether the job can be done without electricity, for example by draining the tank or mixing by hand. If it can, do not use electrical equipment.
- If a tool is still needed, choose battery-powered, extra-low-voltage, or pneumatic equipment.
- Press the test button on the RCD/ELCB at the supply before each shift and record the result.
- Inspect the casing, switch, plug, and cable. Do not use a tool with stripped insulation, a joint that is only taped, or a cracked casing.
- Make sure the cord reel is in good condition, is unwound when carrying heavy loads, and has its connections protected from water.
- Keep the power supply, cord reel, and all joints outside the tank or in a dry, raised spot.
- For tanks, issue a confined-space permit, apply LOTO to pumps and inlet valves, and post an attendant outside.
- Require insulating footwear and gloves, and ban barefoot work on wet surfaces.
- Use a buddy system. No one should work alone in a tank or in a wet area where others cannot see them.
- Train everyone to isolate the power before touching a casualty, then call emergency services.
For tank work, use this list together with your company's confined-space entry procedure. Tanks also bring atmospheric and access hazards.
Lessons for Companies
Subcontracted and informal workers count too. Law 1/1970 applies to all workplaces, not only large factories. Foremen, small builders, and renovation clients can start with simple steps: one RCD-protected cord reel, a tool check every morning, and no barefoot work.
Helpers and contractors on industrial estates. News reports do not say how the helper in the second case was employed. Cleaning tanks, pits, and basins on industrial estates is often given to helpers or third parties. Whoever does the work, the host company should make sure the job goes through the permit system, the worker receives a hazard induction, and the equipment has been inspected.
Review routine tasks. Mixing cement and draining tanks feel ordinary, so they rarely get a job safety analysis. Two deaths on the same day are a strong reason to add "portable electric tools in wet areas" to your hazard register, with LOTO and permit-to-work (PTW) controls where relevant.
Wait for the findings, but act now. Preventive fixes do not need to wait for the investigation. Spot checks on extension reels, temporary outlets, and submersible pumps can happen this week.
Sources
- Tragis, Pekerja di Kendal Tewas Diduga Tersengat Listrik saat Mengaduk Semen (Suara Jateng, 25 November 2026)
- Pekerja di Brangsong Kendal Tewas Tersengat Listrik saat Mengaduk Semen (Puskapik, 25 November 2026)
- Diduga Tersengat Listrik saat Bekerja, Pekerja di Kawasan Industri Kendal Meninggal (Puskapik, 25 November 2026)
- Permenaker No. 12 of 2015 on Electrical OHS in the Workplace (JDIH Kemnaker, accessed 27 November 2026)
- Permenaker No. 33 of 2015 (JDIH Kemnaker, accessed 27 November 2026)
- Law No. 1 of 1970 on Work Safety (JDIH Kemnaker) and text transcription (Wikisource, accessed 27 November 2026)
- Ground-Fault Circuit Interrupters (GFCI) (OSHA, accessed 27 November 2026)
- 29 CFR 1926.404 Wiring Design and Protection (OSHA, accessed 27 November 2026)
Frequently asked questions
Has the cause of the Kendal electrocution deaths been confirmed?
No. Police describe both as preliminary suspicions, and in the Brangsong case the drill and extension reel were seized as evidence.
Why is it dangerous to use an electric drill barefoot?
Bare feet on a wet surface make it easier for current from a faulty tool to pass through the body to earth. Insulating footwear reduces that path, but it is no substitute for an RCD and tool inspection.
Can an electric water pump be used while cleaning a tank from the inside?
Ideally, the tank should be drained and cleaned with no electrical equipment inside. If a pump is unavoidable, use a pneumatic pump or put an RCD at the supply, keep all joints outside, and work under a confined-space permit with an attendant.
Which regulations govern electrical safety at work in Indonesia?
The main ones are Law No. 1 of 1970 and Permenaker No. 12 of 2015, as amended by Permenaker No. 33 of 2015. Their current status should be checked against the official text.